You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
On Scan i reveive the following Advertising information:
Packet received from: 90:84:2B:4A:3A:0C
PAYLOAD: 31 bytes
02-01-06-11-07-23-D1-BC-EA-5F-78-23-16-DE-EF-12-12-23-16-00-00-09-FF-97-03-00-80-06-00-61-00
128-Bit UUID:: 00001623-1212-EFDE-1623-785FEABCD123
MAN SPEC DATA: 97-03-00-80-06-00-61-00
It seems, that not all bytes (Technic Hub specific) are explained in doc ?!
After having set notifcation on characteristic, i got the following data set:
--> Specific to hardware Ports A-D:
Data revieved: 0F-00-04-00-01-2F-00-00-10-00-00-00-10-00-00
Data revieved: 0F-00-04-01-01-2F-00-00-10-00-00-00-10-00-00
Data revieved: 0F-00-04-02-01-2E-00-00-10-00-00-00-10-00-00
Data revieved: 0F-00-04-03-01-2E-00-00-10-00-00-00-10-00-00
2F,2E is meant for new technic L and XL Motor, not listed in doc ?!
--> A number of internal devices connected to internal ports
Data revieved: 0F-00-04-32-01-17-00-00-00-00-10-00-00-00-10
Data revieved: 0F-00-04-3B-01-15-00-00-00-00-10-00-00-00-10
Data revieved: 0F-00-04-3C-01-14-00-00-00-00-10-00-00-00-10
Data revieved: 0F-00-04-3D-01-3C-00-00-00-00-10-00-00-00-10
Data revieved: 0F-00-04-60-01-3C-00-01-00-00-00-01-00-00-00
Data revieved: 0F-00-04-61-01-39-00-01-00-00-00-01-00-00-00
Data revieved: 0F-00-04-62-01-3A-00-01-00-00-00-01-00-00-00
Data revieved: 0F-00-04-63-01-3B-00-01-00-00-00-01-00-00-00
Data revieved: 0F-00-04-64-01-36-00-01-00-00-00-01-00-00-00
--> Most of the devices / Functions are not listed ?!
Please add missing informations in next release and please explain in more detail the meaning of the values
Thanks in advance and nice weekend.
Happy new year ;-)
The text was updated successfully, but these errors were encountered:
Hello all,
i wish you a happy ew year , even if it is a litte bit too early ;-)
Most of all: Many thanks for publishing the documentation.
Thinks i have noticed:According from version 3.0.0 of the documentation
#1: Section 2 - Advertising:
On Scan i reveive the following Advertising information:
Packet received from: 90:84:2B:4A:3A:0C
PAYLOAD: 31 bytes
02-01-06-11-07-23-D1-BC-EA-5F-78-23-16-DE-EF-12-12-23-16-00-00-09-FF-97-03-00-80-06-00-61-00
128-Bit UUID:: 00001623-1212-EFDE-1623-785FEABCD123
MAN SPEC DATA: 97-03-00-80-06-00-61-00
It seems, that not all bytes (Technic Hub specific) are explained in doc ?!
#2: 3.8.1. Hub Attached I/O Message Format
After having set notifcation on characteristic, i got the following data set:
--> Specific to hardware Ports A-D:
Data revieved: 0F-00-04-00-01-2F-00-00-10-00-00-00-10-00-00
Data revieved: 0F-00-04-01-01-2F-00-00-10-00-00-00-10-00-00
Data revieved: 0F-00-04-02-01-2E-00-00-10-00-00-00-10-00-00
Data revieved: 0F-00-04-03-01-2E-00-00-10-00-00-00-10-00-00
2F,2E is meant for new technic L and XL Motor, not listed in doc ?!
--> A number of internal devices connected to internal ports
Data revieved: 0F-00-04-32-01-17-00-00-00-00-10-00-00-00-10
Data revieved: 0F-00-04-3B-01-15-00-00-00-00-10-00-00-00-10
Data revieved: 0F-00-04-3C-01-14-00-00-00-00-10-00-00-00-10
Data revieved: 0F-00-04-3D-01-3C-00-00-00-00-10-00-00-00-10
Data revieved: 0F-00-04-60-01-3C-00-01-00-00-00-01-00-00-00
Data revieved: 0F-00-04-61-01-39-00-01-00-00-00-01-00-00-00
Data revieved: 0F-00-04-62-01-3A-00-01-00-00-00-01-00-00-00
Data revieved: 0F-00-04-63-01-3B-00-01-00-00-00-01-00-00-00
Data revieved: 0F-00-04-64-01-36-00-01-00-00-00-01-00-00-00
--> Most of the devices / Functions are not listed ?!
Please add missing informations in next release and please explain in more detail the meaning of the values
Thanks in advance and nice weekend.
Happy new year ;-)
The text was updated successfully, but these errors were encountered: