!--------- USER INPUT FILE --------------------------------------------------------------------------------------------!
!----------------------------------------------------------------------------------------------------------------------!
! - compile solver with: gfortran.exe -fopenmp -O3 conductivitySolver.f90 -o solverRun.exe
! - number of cpus/threads has to be adjusted with environment variable OMP_NUM_THREADS, e.g. on windows 11 --> $env:OMP_NUM_THREADS=8
integer, parameter :: nx = 150 !Image width
integer, parameter :: ny = 150 !Image height
integer, parameter :: nz = 150 !Image depth
integer, parameter :: voxelRes=1 !DO NOT CHANGE !VoxelResolution of input-raw data --> SHOULD STAY 1, VALUE DOES NOT REALLY HAVE INFLUENCE ON RESULT, MIGHT BE CHANGED TO TYPE REAL IN FUTURE VERSION
integer, parameter :: realPrecision=2 !floating-point precision: 1 (single) or 2 (double)
integer, parameter :: nIteration=10000 !max. number of iterations
real(kind=4*realPrecision), parameter :: targetResidual=1e-6 !target residual
integer(kind=1), parameter :: bitLength = 8 !Bites per pixel, typically grey-values in raw images are stored as either 8-bit or 16-bit integers
integer, dimension(2) :: rawValues=[0,255] !bit-grayvalues of each phase (unsigned format)
real(kind=4*realPrecision), dimension(2) :: correspConductivity=[0.026,8.0] !conductivity of each phase (only double value, e.g. 1.0)
character(512) :: casePath = './case1/' !END STRING WITH SLASH !path to case folder (place raw-data in this folder, results will as be saved there as well)
character(512) :: sampleName = 'spheres_150cube.raw' !input file (veldsteen_poreus_250cube, Berea_2d25um_binary_400cube, spheres_150cube)
character(1) :: evalDirection = 'Z' !direction of calculation (X or Y or Z)
logical :: writeTempertureField=.TRUE. !write calculated temperature-field (.TRUE. or .FALSE.)
logical :: writeFluxField=.TRUE. !write calculated flux-field (.TRUE. or .FALSE.)
!----------------------------------------------------------------------------------------------------------------------!
!--------- If errors occur, please feel free to contact me. I will be happy to help: [email protected] -------------!
!----------------------------------------------------------------------------------------------------------------------!