Pressure Monitor
Roy Dickens ([email protected])
Original date 20-09-2022
Copyright (c) 2022 CC BY
Packing Machine Gas Indicator
----------------------------------------------------------------------------
This program checks that there as is a set pressure to the nitrogen flush
solenoid when gas is requested. If no gas is present then an audible / visual
warning is triggered for a set time then silences itself. This will also have a button
to immediately silence it. If gas pressure returns then the alert will be cancelled
and the program will return to monitoring the the pressure
----------------------------------------------------------------------------
Tolerance from 1 bar ~1.75v
DIP (1 2) Tolerance Steps
00 0% 0
01 10% 20
10 20% 40
11 30% 60
Offset 102 Steps. Sensor range output 0.5v - 4.5v for 0 - 30 psi
----------------------------------------------------------------------------
To calibrate required gas pressure
----------------------------------
1. Set pressure regulator on nitrogen bottle
2. Set DIP3 to calibrate
3. Press silence / calibrate button
4. Lamp and sounder will pulse
5. Reset DIP3 to normal
6. Set tolerance DIP switches 1 & 2 as req.
******************************************************************************
PINS USED
A0 Sensor Analog Attached to pressure sensor
A1 Button Digital Used to calibrate / silence depending on DIP3
A2 Pulse input Digital Attached to gas pulse wire
A3 DIP4 Silence Digital Disables sounder silence timeout
A4 DIP3 Calibrate Digital Used to enable calibration button
A5 DIP2 ToleranceB Digital Tolerance set LSB
A6 DIP1 ToleranceA Digital Tolerance set MSB
A7 Lamp Digital Front panel lamp
B0 Indicator 1 Digital Onboard indicator (last pulse was low on gas)
B1 Indicator 2 Digital Onboard indicator (last pulse was had enough gas)
B2 Sounder Digital Front panel sounder
B3 'Reset Digital Reset IC
Release Notes
Date 4/10/2022
---------------
- Initial release version
Date 28/10/2022
---------------
- Connected spare IC pin A3 to DIP4 this will allow the sounder auto silence to be enabled or disabled
- Adjusted pulse speed so lamp flashes at the same rate as sounder pulses
- Adjusted resistor values to fit availability
- Added momentary GAS button to simulate gas pulse
Date 6/11/2022
---------------
- Fixed problem where button press starts silent alarm timer
Date 24/1/2023
--------------
- Added watchdog reboot functionality
- Added button press to blink indicator once to show user cpu is still working
Date 5/2/2023
--------------
- Changed watchdog register to show reason for last reset.