You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Hello,
In my calculations i am using a charged molecules and write charge in censorc file as 1 and spin 0. However, in part 2 ancopt output the charge and spin of molecules are wrong (See below).
Could you help me resolving this issue.
Censorc
$CRE SORTING SETTINGS:
$GENERAL SETTINGS:
nconf: all # ['all', 'number e.g. 10 up to all conformers']
charge: +1 # ['number e.g. 0']
unpaired: 0 # ['number e.g. 0']
solvent: h2o # ['gas', 'acetone', 'acetonitrile', 'aniline', 'benzaldehyde', 'benzene', 'ccl4', '...']
prog_rrho: xtb # ['xtb']
temperature: 298.15 # ['temperature in K e.g. 298.15']
trange: [273.15, 378.15, 5] # ['temperature range [start, end, step]']
multitemp: on # ['on', 'off']
evaluate_rrho: on # ['on', 'off']
ancopt part
-------------------------------------------------
| Calculation Setup |
-------------------------------------------------
program call : /mechthild/software/apps/xtb-6.4.0/bin/xtb coord --opt normal --tm -I opt.inp
hostname : node026
coordinate file : coord
number of atoms : 24
number of electrons : 49
charge : 0
spin : 0.5
first test random number : 0.66531624437863
The text was updated successfully, but these errors were encountered:
Hi,
xtb is only used as a driver for ANCopt and the external call to either TM or ORCA has the correct charge and spin information. In the case of TM this is considered during the creation of the control file and for ORCA this is written into the file inp .
You can have a look at your orca input file or control file and the correct charge information should be present there. However, I can see that this seemingly wrong charge info in xtb is confusing and I will remedy this in the next update.
Hello,
In my calculations i am using a charged molecules and write charge in censorc file as 1 and spin 0. However, in part 2 ancopt output the charge and spin of molecules are wrong (See below).
Could you help me resolving this issue.
Censorc
$CRE SORTING SETTINGS:
$GENERAL SETTINGS:
nconf: all # ['all', 'number e.g. 10 up to all conformers']
charge: +1 # ['number e.g. 0']
unpaired: 0 # ['number e.g. 0']
solvent: h2o # ['gas', 'acetone', 'acetonitrile', 'aniline', 'benzaldehyde', 'benzene', 'ccl4', '...']
prog_rrho: xtb # ['xtb']
temperature: 298.15 # ['temperature in K e.g. 298.15']
trange: [273.15, 378.15, 5] # ['temperature range [start, end, step]']
multitemp: on # ['on', 'off']
evaluate_rrho: on # ['on', 'off']
ancopt part
-------------------------------------------------
| Calculation Setup |
-------------------------------------------------
The text was updated successfully, but these errors were encountered: