Installation

Build application

Download Repository

Download or clone the repository source code to your workstation.
archiving_visualization_github

  • Trough terminal:
git clone https://github.com/industrial-edge/archiving-and-visualization.git
  • Trough VSCode:
    CTRL+↑ SHIFT+P or F1 to open VSCode's command pallette and type git clone:

VS Code Git Clone command

Build docker image

  • Navigate into src/influxdb and src/mqtt-service and find the file named Dockerfile.example. The Dockerfile.example is an example Dockerfile that can be used to build the docker image(s) of the service(s) that runs in this application example. If you choose to use these, rename them to Dockerfile before proceeding
  • Open a console in the root folder (where the docker-compose file is)
  • Use the docker compose build (replaces the older docker-compose build) command to build the docker image of the service which is specified in the docker-compose.yml file.
  • These Docker images can now be used to build your app with the Industrial Edge App Publisher
  • docker images can be used to check for the images

Upload Application to Industrial Edge Management

Please find below a short description how to publish your application in your IEM.

For more detailed information please see the section for uploading apps to the IEM.

Connect your Industrial Edge App Publisher

  • Connect your Industrial Edge App Publisher to your docker engine
  • Connect your Industrial Edge App Publisher to your Industrial Edge Management

Create new Application in Industrial Edge Management

  1. Create a new Project or select a existing one
  2. Create new Application
  3. Import the docker-compose file using the Import YAML button

Warnings
Build (Detail) (services >> mqtt-service >> build) is not supported
Build (Detail) (services >> influxdb >> build) is not supported.
are caused by the fact, that the docker-compose file defines build commands for local build of the application's docker image which are not supported by the Industrial Edge App Publisher and can safely be ignored

  1. Click on Review and Validate & Create. When asked about the redirect URL, select the endpoint of the influxdb service:

iearedirect urlp

  • Start Upload to transfer the app to Industrial Edge Management
  • Further information about using the Industrial Edge App Publisher can be found in the IE Hub

Configure Databus and OPC UA Connector

  1. Configure a user with password in the Databus for the OPC UA Connector and the Archiving & Operation Application for publishing and subscribing to topics on the Databus.

    User name: edge 
    Password: edge 
    Topic: ie/# 
    Permission: Publish and Subscribe

iedatabus

  1. Open OPC UA Connector from your Industrial Edge Management and add the PLC as a data source. You are free to choose whichever name for datasource you like, but take a note of the name as you would need to specify the same name in the configuration of the app during its installation.

  2. Add variables to collect data from PLC as described in pre-requisites section Select following Datapoints using the Browse functionality:

  • GDB.signals.tankSignals.actLevel - (Read/100ms)
  • GDB.signals.tankSignals.actTemperature - (Read/100ms)
  • GDB.process.numberProduced - (Read/100ms)
  • GDB.process.numberFaulty - (Read/100ms)
  • GDB.hmiSignals.HMI.Nextbottle - (Read&Write/100ms)
In case of browse timeout you can also add the tags manually Click to show/collapse.
  • n=3;s="GDB"."signals"."tankSignals"."actLevel"
  • n=3;s="GDB"."signals"."tankSignals"."actTemperature"
  • n=3;s="GDB"."process"."numberProduced"
  • n=3;s="GDB"."process"."numberFaulty"
  • n=3;s="GDB"."hmiSignals"."HMI"."NextBottle"

opc ua connector

  1. Enter Databus credentials


Add Edge App configuration & upload configuration file to Industrial Edge Management

The MQTT Service can be configured with a form. The form is based on JSONForms. If no configuration is provided during app installation, the application uses default values seen in the following json-file config-default.json:

{
    "MQTT": {
        "HOST": "ie-databus",
        "PORT": "1883",
        "USERNAME": "edge",
        "PASSWORD": "edge",
        "TOPIC_NAME": "ie/d/j/simatic/v1/opcuac1/dp",
        "METADATA_TOPIC_NAME": "ie/m/j/simatic/v1/opcuac1/dp",
        "DATA_SOURCE_NAME": "Tank"
    },
    "INFLUXDB": {
        "HOST": "http://influxdb:8086",
        "PORT": "8086",
        "ORG": "edge",
        "BUCKET": "databus_values",
        "TOKEN": "industrialedge"
    }
}

MQTT

  • HOST: This is the service name of the Databus
  • PORT: This is the port of the Databus
  • USER, PASSWORD: The user and password are configured in the Databus and used in the OPC UA Connector for accessing (publish, subscribe) to topics on the Databus
  • TOPIC_NAME: This is the default topic root path for data of the OPC UA Connector
  • METADATA_TOPIC_NAME: This is the default topic root path for metadata of the OPC UA Connector
  • DATA_SOURCE_NAME The data source Name is configured in the OPC UA Connector. Insert here the data source Name for your PLC-Connection

InfluxDB

  • HOST: Service name of InfluxDB which is specified in docker-compose. Do not change unless you are trying to connect to a different instance of influxdb.
  • PORT: Port on which the InfluxDB service is running. Do not change unless you are trying to connect to a different instance of influxdb.
  • ORG: Initial organization created in the Influxdb upon creation. This value needs to correspond to the value set in docker-compose.yml file.
  • BUCKET: InfluxDB can have multiple database running in the same instance. Data which are collected from databus are written to that database. This value needs to correspond to the value set in docker-compose.yml file.
  • TOKEN: Administrator token used for authorization of your app in order to bootstrap the app and read and write data to the database. This value needs to correspond to the value set in docker-compose.yml file.

Add Configuration to application

  1. Go to IE Publisher and select the newly created application. Then click the "+ Configurations" button.

Publisher configuration Publisher configuration - Create new configuration

  1. Add new configuration and enter all required fields:

    Display Name: Configuration
    Description: JSONForms Configuration
    Host Path: ./cfg-data/
    Add Template 
    - Name: JSONForms
    - Description: JSONForms Configuration
    - JSON Schema: set checkbox

In the final step, add the file /cfg-data/config.json as a template file. This template was created with JSON Schema. To find out how to create your own template check out the IEM Operations Documentation.

edge-app-configuration

Install Application on Industrial Edge Device

Edge App configuration

Fill out Input-Form and select checkbox (check box green)

edge-app-configuration

Databus

  • MQTT Broker IP: optional
  • PORT: optional

User

  • Username: required
  • Password: required

Connector Configuration (OPC UA Connector)

  • Data Source Name: required
  • Connector Metadata Topic: optional

InfluxDB

  • InfluxDB IP: optional
  • InfluxDB Port: optional
  • Bucket Name: optional
  • Organization: optional
  • Token: optional

Install Edge App

Install Edge Application to Industrial Edge Device and select app configuration Install Application


Configure InfluxDB Dashboard

  1. Open Industrial Edge Device in Browser and open installed application
  2. Login to InfluxDB UI using the credentials set in docker-compose.yml, by default:
    Username: root
    Password: changeMe1!
  3. InfluxDB Welcome Page: Open Dashboards from the left menu
  4. Click "+ Create Dashboards" button
  5. Select "Import Dashboard"
  6. Select the file located in /src/influxdb/Dashboards/bottle_line_visualization.json and click on "Import JSON as Dashboard"
  7. Open the newly imported Dashboard by clicking on "Bottle Line Visualization"

Note
Upon creation the Dashboard will show no data. It may take a moment before enough data coming from the Databus will be stored in the influxDB database and subsequently before it can be plotted in the provided dashboard.