# import firebase_admin
# from firebase_admin import credentials, db
# from flask_caching import Cache
# from flask_restx import Api
# from flask import Flask, request
# import time
# from azure_monitor import log_custom_event, log_operation_duration, log_exception
# from data_handler import is_valid_sensor_data, process_sensor_data
# from error_handling import handle_error
# app = Flask(__name__)
# # Initialize Firebase
# cred = credentials.Certificate("secrets.json")
# firebase_admin.initialize_app(cred, {
# 'databaseURL': "https://arcus-c9ae1-default-rtdb.firebaseio.com/"
# })
# root_ref = db.reference('/')
# # Configure Flask-Caching
# cache = Cache(app, config={'CACHE_TYPE': 'simple'})
# api = Api(app, version='1.0', title='MukoApi', description='Arcus API', doc='/apidocs/')
# app.errorhandler(Exception)(handle_error)
# @cache.cached(timeout=300) # Cache the result for 300 seconds
# @app.route('/update_data', methods=['POST'])
# def update_data():
# try:
# data = request.data.decode("utf-8")
# if not is_valid_sensor_data(data):
# log_custom_event('InvalidSensorData', properties={'data': data})
# return "Invalid sensor data format", 400
# start_time = time.time()
# sensors_data = process_sensor_data(data)
# # Log the duration of this operation
# log_operation_duration('UpdateDataDuration', start_time)
# root_ref.update(sensors_data)
# log_custom_event('SensorDataUpdated', properties={'data': data})
# return "Sensor data updated"
# except Exception as e:
# log_exception()
# raise e
# @cache.cached(timeout=300) # Cache the result for 300 seconds
# @app.route('/control_pump', methods=['GET'])
# def control_pump():
# try:
# pump_status = root_ref.child("sensor1").child("pump_status").get()
# if pump_status is not None:
# pump_status = pump_status == "on" # Convert to a boolean
# # Depending on the "pump_status" value, take appropriate actions to control the pump
# response_message = ""
# if pump_status:
# response_message = "Pump turned on"
# else:
# response_message = "Pump turned off"
# else:
# response_message = "Pump status not found in the database"
# return response_message
# except Exception as e:
# log_exception()
# raise e
# if __name__ == '__main__':