[argoclima] Review remarks: ID shortning
Browse files Browse the repository at this point in the history
* Thing type ID renames: argoclima-local -> local,
  argoclima-remote->remote
* Dropped '-channel' suffix from channel type IDs
* Added % unit hint to eco-power-limit

Signed-off-by: Mateusz Bronk <[email protected]>
  • Loading branch information
mbronk committed Jun 29, 2024
1 parent 22ad009 commit 30dabd2
Show file tree
Hide file tree
Showing 4 changed files with 172 additions and 167 deletions.
61 changes: 33 additions & 28 deletions bundles/org.openhab.binding.argoclima/README.md
Original file line number Diff line number Diff line change
Expand Up @@ -16,8 +16,8 @@ See also [Argo protocol details](#argo-protocol-details) to find out more about

## Supported Things

- `argoclima-remote`: Represents a HVAC device which is controlled remotely - through vendor's web application
- `argoclima-local`: Represents a locally available device, which openHAB interacts with directly *(or indirectly, through a stub server)*. Refer to [Connection Modes](#connection-modes) for more details.
- `remote`: Represents a HVAC device which is controlled remotely - through vendor's web application
- `local`: Represents a locally available device, which openHAB interacts with directly *(or indirectly, through a stub server)*. Refer to [Connection Modes](#connection-modes) for more details.

The binding has been primarily developed and tested using [Ulisse 13 DCI ECO Wi-Fi](https://argoclima.com/en/prodotti/argo-ulisse-eco/) device.

Expand All @@ -29,7 +29,7 @@ The binding does not support device auto-discovery (as the devices don't announc

## Thing Configuration

### `argoclima-remote` Thing Configuration
### `remote` Thing Configuration

| Name | Type | Description | Default | Required | Advanced |
|------------------|---------|---------------------------------------------------------------|---------------|----------|----------|
Expand All @@ -39,7 +39,7 @@ The binding does not support device auto-discovery (as the devices don't announc
| oemServerAddress | text | The Argo server's IP or hostname, used for communications. | 31.14.128.210 | no | yes |
| oemServerPort | integer | The Argo server's port. | 80 | no | yes |

### `argoclima-local` Thing Configuration
### `local` Thing Configuration

| Name | Type | Description | Default | Required | Advanced |
|-------------------------------------------|----------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------|----------|----------|
Expand All @@ -60,7 +60,7 @@ The binding does not support device auto-discovery (as the devices don't announc
### General Device Configuration (dynamic)

These parameters are modeled as thing configuration, but are actually configuring behavior of the HVAC device itself (when in certain modes).
The same values apply to **both** `argoclima-remote` and `argoclima-local`.
The same values apply to **both** `remote` and `local`.

| Name | Type | Description | Default | Required | Advanced |
|------------------------|-----------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------|----------|----------|
Expand Down Expand Up @@ -110,17 +110,17 @@ Both thing types are functionally equivalent and support the same channels.

```java
//BASIC MODES examples
Thing argoclima:argoclima-remote:argoHvacRemote "Argo HVAC (via Argo remote API)" @ "Living Room" [
Thing argoclima:remote:argoHvacRemote "Argo HVAC (via Argo remote API)" @ "Living Room" [
username="<yourArgoLogin>",
password="<yourArgoPassword>"
]


Thing argoclima:argoclima-local:argoHvacLocalDirect "Argo HVAC (connected locally)" @ "Living Room" [
Thing argoclima:local:argoHvacLocalDirect "Argo HVAC (connected locally)" @ "Living Room" [
hostname="192.168.0.3"
]

Thing argoclima:argoclima-local:argoHvacLocalDirectEx "Argo HVAC (connected locally) - extended example (with explicit options)" [
Thing argoclima:local:argoHvacLocalDirectEx "Argo HVAC (connected locally) - extended example (with explicit options)" [
hostname="192.168.0.3",
connectionMode="LOCAL_CONNECTION",
refreshInterval=30,
Expand All @@ -143,14 +143,14 @@ Both thing types are functionally equivalent and support the same channels.
]

//ADVANCED MODES examples
Thing argoclima:argoclima-local:argoHvacLocalWithPassthroughIndirect "Argo HVAC (accessible only indirectly, via pass-through mode)" [
Thing argoclima:local:argoHvacLocalWithPassthroughIndirect "Argo HVAC (accessible only indirectly, via pass-through mode)" [
hostname="192.168.4.2", // Doesn't have to be reachable!
connectionMode="REMOTE_API_PROXY",
useLocalConnection=false
]


Thing argoclima:argoclima-local:argoHvacLocalWithPassthroughPlusDirectEx "Argo HVAC (accessible both indirectly and directly, via pass-through mode, with explicit options)" [
Thing argoclima:local:argoHvacLocalWithPassthroughPlusDirectEx "Argo HVAC (accessible both indirectly and directly, via pass-through mode, with explicit options)" [
hostname="192.168.0.3", // Direct address of the device (reachable from openHAB)
connectionMode="REMOTE_API_PROXY",
Expand All @@ -172,7 +172,7 @@ Both thing types are functionally equivalent and support the same channels.
]


Thing argoclima:argoclima-local:argoHvacLocalWithStub "Argo HVAC (accessible both indirectly and directly with a stub) - **RECOMMENDED MODE**" [
Thing argoclima:local:argoHvacLocalWithStub "Argo HVAC (accessible both indirectly and directly with a stub) - **RECOMMENDED MODE**" [
hostname="192.168.0.3", // Has to be reachable, since useLocalConnection is true (default)
connectionMode="REMOTE_API_STUB",
localDeviceIP="192.168.4.2" // Or use matchAnyIncomingDeviceIp=true
Expand All @@ -185,85 +185,85 @@ Both thing types are functionally equivalent and support the same channels.
Group GArgoClimaHVACRemote "Ulisse 13 DCI ECO - remote mode" ["HVAC"]

Switch ArgoClimaHVACRemote_Power "Power" <switch> (GArgoClimaHVACRemote) {
channel="argoclima:argoclima-remote:argoHvacRemote:ac-controls#power"
channel="argoclima:remote:argoHvacRemote:ac-controls#power"
}

String ArgoClimaHVACRemote_Mode "Mode" <climate> (GArgoClimaHVACRemote) ["Control"] {
channel="argoclima:argoclima-remote:argoHvacRemote:ac-controls#mode"
channel="argoclima:remote:argoHvacRemote:ac-controls#mode"
}

Number:Temperature ArgoClimaHVACRemote_SetTemperature "Set Temperature" <temperature> (GArgoClimaHVACRemote) ["Temperature", "Setpoint"] {
channel="argoclima:argoclima-remote:argoHvacRemote:ac-controls#set-temperature",
channel="argoclima:remote:argoHvacRemote:ac-controls#set-temperature",
unit="°C",
stateDescription="" [ pattern="%.1f °C", readOnly=false, min=10.0, max=36.0, step=0.5],
widget="oh-stepper-card" [ min=10, max=36, step=0.5, autorepeat=true],
listWidget="oh-stepper-item" [min=10, max=36, step=0.5, autorepeat=true]
}

Number:Temperature ArgoClimaHVACRemote_CurrentTemperature "Current Temperature" <temperature> (GArgoClimaHVACRemote) ["Temperature", "Measurement"] {
channel="argoclima:argoclima-remote:argoHvacRemote:ac-controls#current-temperature"
channel="argoclima:remote:argoHvacRemote:ac-controls#current-temperature"
}

String ArgoClimaHVACRemote_FanSpeed "Fan Speed" <fan> (GArgoClimaHVACRemote) {
channel="argoclima:argoclima-remote:argoHvacRemote:ac-controls#fan-speed"
channel="argoclima:remote:argoHvacRemote:ac-controls#fan-speed"
}

Switch ArgoClimaHVACRemote_EcoMode "Eco Mode" <vacation> (GArgoClimaHVACRemote) {
channel="argoclima:argoclima-remote:argoHvacRemote:modes#eco-mode"
channel="argoclima:remote:argoHvacRemote:modes#eco-mode"
}

Switch ArgoClimaHVACRemote_TurboMode "Turbo Mode" <party> (GArgoClimaHVACRemote) {
channel="argoclima:argoclima-remote:argoHvacRemote:modes#turbo-mode"
channel="argoclima:remote:argoHvacRemote:modes#turbo-mode"
}

Switch ArgoClimaHVACRemote_NightMode "Night Mode" <moon> (GArgoClimaHVACRemote) {
channel="argoclima:argoclima-remote:argoHvacRemote:modes#night-mode"
channel="argoclima:remote:argoHvacRemote:modes#night-mode"
}

String ArgoClimaHVACRemote_ActiveTimer "Active timer" <calendar> (GArgoClimaHVACRemote) {
channel="argoclima:argoclima-remote:argoHvacRemote:timers#active-timer"
channel="argoclima:remote:argoHvacRemote:timers#active-timer"
}

Number:Time ArgoClimaHVACRemote_DelayTimer "Delay timer value" <time> (GArgoClimaHVACRemote) ["Setpoint"] {
channel="argoclima:argoclima-remote:argoHvacRemote:timers#delay-timer",
channel="argoclima:remote:argoHvacRemote:timers#delay-timer",
unit="min",
stateDescription="" [ pattern="%d min", readOnly=false, min=10, max=1190, step=10 ],
widget="oh-stepper-card" [ min=10, max=1190, step=10, autorepeat=true],
listWidget="oh-stepper-item" [min=10, max=1190, step=10, autorepeat=true]
}

Switch ArgoClimaHVACRemote_IFeelEnabled "Use iFeel Temperature" <network> (GArgoClimaHVACRemote) {
channel="argoclima:argoclima-remote:argoHvacRemote:settings#ifeel-enabled"
channel="argoclima:remote:argoHvacRemote:settings#ifeel-enabled"
}

Switch ArgoClimaHVACRemote_DeviceLights "Device Lights" <light> (GArgoClimaHVACRemote) {
channel="argoclima:argoclima-remote:argoHvacRemote:settings#device-lights"
channel="argoclima:remote:argoHvacRemote:settings#device-lights"
}

String ArgoClimaHVACRemote_TemperatureDisplayUnit "Temperature Display Unit []" <settings> (GArgoClimaHVACRemote) {
stateDescription="" [ options="SCALE_CELSIUS=°C,SCALE_FAHRENHEIT=°F" ],
commandDescription="" [ options="SCALE_CELSIUS=°C,SCALE_FAHRENHEIT=°F" ],
channel="argoclima:argoclima-remote:argoHvacRemote:settings#temperature-display-unit"
channel="argoclima:remote:argoHvacRemote:settings#temperature-display-unit"
}

Number:Dimensionless ArgoClimaHVACRemote_EcoPowerLimit "Power limit in eco mode" <price> (GArgoClimaHVACRemote) ["Setpoint"] {
channel="argoclima:argoclima-remote:argoHvacRemote:settings#eco-power-limit",
channel="argoclima:remote:argoHvacRemote:settings#eco-power-limit",
unit="%",
stateDescription=" " [ pattern="%d %%", readOnly=false, min=30, max=99, step=1 ],
widget="oh-stepper-card" [ min=30, max=99, step=1, autorepeat=true],
listWidget="oh-stepper-item" [min=30, max=99, step=1, autorepeat=true]
}

String ArgoClimaHVACRemote_ModeEx "Extended Mode" <heating> (GArgoClimaHVACRemote) {
channel="argoclima:argoclima-remote:argoHvacRemote:unsupported#mode-ex"
channel="argoclima:remote:argoHvacRemote:unsupported#mode-ex"
}

String ArgoClimaHVACRemote_SwingMode "Airflow Direction" <flow> (GArgoClimaHVACRemote) {
channel="argoclima:argoclima-remote:argoHvacRemote:unsupported#swing-mode"
channel="argoclima:remote:argoHvacRemote:unsupported#swing-mode"
}

Switch ArgoClimaHVACRemote_FilterMode "Filter Mode" <switch> (GArgoClimaHVACRemote) {
channel="argoclima:argoclima-remote:argoHvacRemote:unsupported#filter-mode"
channel="argoclima:remote:argoHvacRemote:unsupported#filter-mode"
}
```

Expand Down Expand Up @@ -422,3 +422,8 @@ The author would like to thank the following individuals:
While most of the learnings come from analyzing the JavaScript code in Argo's own application and network captures, the HA integration has proven **invaluable** as a secondary/confirmed source and allowed to validate a few concepts early on!
- In case you're experiencing issues, make sure to read the HomeAssistant binding's [README](https://github.com/nyffchanium/argoclima-integration/blob/master/readme.md) as well, for useful troubleshooting info!
- [@lallinger](https://github.com/lallinger) for a [dummy server](https://github.com/nyffchanium/argoclima-integration/tree/master/dummy-server) which was the idea that served as the cornerstone of the stub server built into this binding (which later got extended to do something useful, instead of just keeping the device happy).

## Disclaimer

This project is not affiliated with, funded, or in any way associated with Argoclima S.p.A.
All third-party product, company names, logos and trademarks™ or registered® trademarks remain the property of their respective holders.
Original file line number Diff line number Diff line change
Expand Up @@ -31,8 +31,8 @@ public class ArgoClimaBindingConstants {
/////////////
// List of all Thing Type UIDs
/////////////
public static final ThingTypeUID THING_TYPE_ARGOCLIMA_LOCAL = new ThingTypeUID(BINDING_ID, "argoclima-local");
public static final ThingTypeUID THING_TYPE_ARGOCLIMA_REMOTE = new ThingTypeUID(BINDING_ID, "argoclima-remote");
public static final ThingTypeUID THING_TYPE_ARGOCLIMA_LOCAL = new ThingTypeUID(BINDING_ID, "local");
public static final ThingTypeUID THING_TYPE_ARGOCLIMA_REMOTE = new ThingTypeUID(BINDING_ID, "remote");

/////////////
// Thing configuration parameters
Expand Down