Pmod CMPS2

Contents of Readme

  1. About
  2. Brief information about Pmod CMPS2
  3. Interface Description
  4. Tests
  5. Status Information
  6. Issues
  7. Licence

About

Simple interface for the Digilent Pmod CMPS2 or any other module with MMC3416xPJ.

Brief information about Pmod TMP3

The Digilent Pmod CMPS2 is a 3-Axis Magnetometer. It contains Memsic's MMC3416xPJ 3-axis Magnetic Sensor.

Interface Description

Module cmps2 can be used as a simple interface for the Pmod CMPS2 (or any other module with MMC3416xPJ).

Module cmps2 offers two measurement modes. Normal measurement (initiated with measure) does a set measurement and subtracts existing offsets from measurement results. Calibration measurement (initiated with calibrate) does a reset measurement followed by a set measurement. Using these measurement results, calibrated measurement values and new offsets are calculated. Measurement results calculated via (set results - reset results) / 2 and offset values calculated via (set results + reset results) / 2.

IOs:

Port Type Width Description
clk I 1 System Clock
rst I 1 System Reset
clkI2Cx2 I 1 I²C Clock source
SCL* IO 1 I²C Clock Pin
SDA* IO 1 I²C Data Pin
x_axis O 16 Measurement result for X axis
y_axis O 16 Measurement result for Y axis
z_axis O 16 Measurement result for Z axis
resolution I 2 Resolution configuration of MMC3416xPJ
x_offset O 16 Calculated offset for X axis
y_offset O 16 Calculated offset for Y axis
z_offset O 16 Calculated offset for Z axis
calibrate I 1 Initiate a measurement with a new calibration
measure I 1 Initiate a measurement with using existing calibration
i2cBusy O 1 Another master is using I²C bus
valid O 1 New measurement results ready and valid

I: Input O: Output

* contain pins _i, _o and _t

Note: Maximum frequency of clkI2Cx2 is 800 kHz, SCL will have half of this frequency.

Timing:

Time takes from initiation of new measurement and obtaining valid measurement results for diffent cases can be found at the table below.

resolution calibrate measure
2'b00 (16 bit) 15,98 ms 7,743ma
2'b01 (16 bit) 8,927 ms 4,217 ms
2'b10 (14 bit) 5,298 ms 2,402 ms
2'b11 (12 bit) 3,485 ms 1,495 ms

(Synthesized) Utilization on Artix-7:

  • Slice LUTs: 234 (as Logic)
  • Slice Registers: 251 (as Flip Flop)

Test

The CMPS2 interface module tested with test module tester_cmps2.v and constrains Basys3.xdc. I²C pins are monitored via DDiscovery. Right button connected to calibrate, left button connected to measure. Two right most switches are connected to resolution. Seven segment display is used to display x_axis, y_axis and z_axis; controled via two left most switches. Output values are also send via UART on positive edge of valid. They are send in following order: x_axis, y_axis, z_axis, x_offset, y_offset, z_offset. UART configurations are 115200, 8 bits with no parity and 1 bit stop.

Status Information

Last test: 17 June 2021, on Digilent Basys 3.

Issues

  • For some measurements, least significant bit of the result is wrong, resulting 0.5mG error.

License

CERN Open Hardware Licence Version 2 - Weakly Reciprocal