44 changes: 22 additions & 22 deletions docs/docs/general/features.md
Original file line number Diff line number Diff line change
Expand Up @@ -83,7 +83,7 @@ CCCM limits the charge/discharge current depending on the highest/lowest cell vo
* between `2.8V - 2.9V` → `5A `discharge
* below `<= 2.70V` &rarr; `0A` discharge

### Temprature
### Temperature

* `CCCM_T_ENABLE = True/False`
* `DCCM_T_ENABLE = True/False`
Expand Down Expand Up @@ -121,27 +121,27 @@ If the `MAX_CELL_VOLTAGE` \* `cell count` is reached for `MAX_VOLTAGE_TIME_SEC`

## BMS feature comparison

| Feature | Ant | Daly | ECS | HLPdataBMS4S | JK BMS | Life/Tian Power | LLT/JBD | MNB <sup>(1)</sup> | Renogy | Seplos | Sinowealth <sup>(1)</sup> |
| ---: | :---: | :---: | :---: | :---: | :---: | :---: | :---: | :---: | :---: | :---: | :---: |
| Voltage | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Current | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Power | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| State Of Charge | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Battery temperature | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| MOSFET temperature | No | No | No | No | Yes | No | Yes | No | No | No | No |
| Consumed Ah | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Time-to-go | Calc | Calc | Calc | Calc | Calc | Calc | Calc | Calc | Calc | Calc | Calc |
| Min/max cell voltages | Yes | Yes | No | Yes | Yes | Yes | Yes | No | Yes | Yes | Yes |
| Min/max temperature | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Installed capacity | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Available capacity | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Cell details | No | Yes | Yes | Yes | Yes | Yes | Yes | No | Yes | Yes | ? |
| Balancing status | Yes | No | Yes | No | Yes | Yes | No | No | No | No | ? |
| Raise alarms from the BMS | Yes | Yes | Yes <sup>(2)</sup> | Yes | Yes | Yes | Yes | Yes | Yes | Yes | ? |
| History of charge cycles | Yes | Yes | No | No | Yes | Yes | Yes | No | Yes | Yes | Yes |
| Get CCL/DCL from the BMS | No | No | No | No | Yes | No | No | No | No | No | No |
| Charge current control management (CCCM) | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Set battery parameters (DVCC) | Calc | Calc | Yes | Yes | Calc | Calc | Calc | Yes | Calc | Calc | Calc |
| Feature | Ant | Daly | ECS | Heltec | HLPdataBMS4S | JK BMS | Life/Tian Power | LLT/JBD | MNB <sup>(1)</sup> | Renogy | Seplos | Sinowealth <sup>(1)</sup> |
| ---: | :---: | :---: | :---: | :---: | :---: | :---: | :---: | :---: | :---: | :---: | :---: | :---: |
| Voltage | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Current | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Power | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| State Of Charge | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Battery temperature | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| MOSFET temperature | No | No | No | Yes | No | Yes | No | Yes | No | No | No | No |
| Consumed Ah | Yes | Yes | Yes | No | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Time-to-go | Calc | Calc | Calc | Calc | Calc | Calc | Calc | Calc | Calc | Calc | Calc | Calc |
| Min/max cell voltages | Yes | Yes | No | Yes | Yes | Yes | Yes | Yes | No | Yes | Yes | Yes |
| Min/max temperature | Yes | Yes | Yes | No | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Installed capacity | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Available capacity | Yes | Yes | Yes | No | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Cell details | No | Yes | Yes | Yes | Yes | Yes | Yes | Yes | No | Yes | Yes | ? |
| Balancing status | Yes | No | Yes | Yes | No | Yes | Yes | No | No | No | No | ? |
| Raise alarms from the BMS | Yes | Yes | Yes <sup>(2)</sup> | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | ? |
| History of charge cycles | Yes | Yes | No | No | No | Yes | Yes | Yes | No | Yes | Yes | Yes |
| Get CCL/DCL from the BMS | No | No | No | Yes | No | Yes | No | No | No | No | No | No |
| Charge current control management (CCCM) | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Set battery parameters (DVCC) | Calc | Calc | Yes | Calc | Yes | Calc | Calc | Calc | Yes | Calc | Calc | Calc |


`Calc` means that the value is calculated by the driver.
Expand Down
2 changes: 1 addition & 1 deletion docs/docs/general/install.md
Original file line number Diff line number Diff line change
Expand Up @@ -122,7 +122,7 @@ Select `2` for `nightly build` and then select the branch you want to install fr
### BMS specific settings

* ECS BMS &rarr; https://github.com/Louisvdw/dbus-serialbattery/issues/254#issuecomment-1275924313

* HeltecModbus &rarr; in case the modbus slave address of the BMS was adjusted from the factory default, configure the slave addresses to query in config.ini:HELTEC_MODBUS_ADDR. As always the battery settings shall be configured in the BMS already via app or computer.

## How to change the default limits

Expand Down
3 changes: 3 additions & 0 deletions docs/docs/general/supported-bms.md
Original file line number Diff line number Diff line change
Expand Up @@ -22,6 +22,9 @@ Disabled by default since driver version `v0.14.0` as it causes other issues. Se

### &bull; ECS GreenMeter with LiPro

### &bull; HeltecModbus SmartBMS (YanYang BMS)
Communication to the Heltec SmartBMS (which is a rebranded YYBMS) via Modbus/RS485.