at power up:
enable internal pullup and see if the raw ADC value is saturated at Vcc
then enable internal pulldown and see if raw ADC value is stuck at ground
If both of these are true the voltage divider resistors must not be installed. Disable battery sensing.
The text was updated successfully, but these errors were encountered:
at power up:
enable internal pullup and see if the raw ADC value is saturated at Vcc
then enable internal pulldown and see if raw ADC value is stuck at ground
If both of these are true the voltage divider resistors must not be installed. Disable battery sensing.