Read voltage during init fixes #5276 #5332
Merged
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
Power::readPowerStatus is called on startup,
but AnalogBatteryLevel::getBattVoltage
skips the read because 5 seconds have not
elapsed since last_read_time_ms, which
is initialized to zero.
batMv=3100
is reported becauseAnalogBatteryLevel::last_read_value is
initialized as: